Back to browse
PA Solicitation

Environmental System Maintenance Repair

Department of Defense — Department of the Army

Solicitation Number PANRSA-26-P-0000-034216
Posted Date May 12, 2026
Due Date May 26, 2026
Estimated Value Not specified
NAICS Codes 811210
Place of Performance Tobyhanna, PA

Description

Maintenance and repair of its laboratory environment systems located at its TMDE Support Center, Tobyhanna Army — Depot, 11 Hap Arnold Blvd, Tobyhanna, PA 18466. — Under this agreement the Contractor shall furnish all labor, diagnostic software, hardware, documentation, schematics and equipment required to provide evaluation, maintenance and repair to laboratory environmental systems required to maintenance temperature and humidity environments required for calibration and repair of sensitive scientific equipment. The required services shall be provided by the original equipment provider which installed the systems during previous renovations. — Performance Requirements: — Remove existing Temp/Humidity Controller for each of the Three (3) labs and replace with PLC Controller — PLC controller to be housed in a ndw 24x24 NEMA Enclosure — Provide a new stand along PC with VT SCADA to monitor, trend and store all data — Program PLC's to match existing temperature/humidity control — Install new control panels and interface to existing equipment — Startup/Training of new control system

Maintenance and repair of its laboratory environment systems located at its TMDE Support Center, Tobyhanna Army — Depot, 11 Hap Arnold Blvd, Tobyhanna, PA 18466. — Under this agreement the Contractor shall furnish all labor, diagnostic software, hardware, documentation, schematics and equipment required to provide evaluation, maintenance and repair to laboratory environmental systems required to maintenance temperature and humidity environments required for calibration and repair of sensitive scientific equipment. The required services shall be provided by the original equipment provider which installed the systems during previous renovations. — Performance Requirements: — Remove existing Temp/Humidity Controller for each of the Three (3) labs and replace with PLC Controller — PLC controller to be housed in a ndw 24x24 NEMA Enclosure — Provide a new stand along PC with VT SCADA to monitor, trend and store all data — Program PLC's to match existing temperature/humidity control — Install new control panels and interface to existing equipment — Startup/Training of new control system

Create a free account to read the full description

Sign up to access complete RFP details, AI match scores, and more.

Create Free Account